Causes the connector connection to fail
The inner conductor of the connector is smaller in size relative to the outer conductor, and the inner conductor having a lower strength is more likely to cause poor contact and cause the connector to fail. Most of the inner conductors of the connector are elastically connected, for example, a spring claw type elastic connection, a jack slot type elastic connection, a bellows type elastic connection, and the like. The jack slot type elastic connection structure is simple, the processing cost is low, the assembly is convenient, and the application range is the most extensive. 1, the inner conductor is not fixed firmly For assembly purposes, in many RF coaxial connectors (eg, N-type, 3.5 mm), the inner conductor is divided into two sections at the media support and then threaded. However, due to the small diameter of the inner conductor, if the glue is not fixed at the screw connection during assembly, the strength of the inner conductor connection is very poor, especially for some sm...